『Intelligent spiral vortex flowmeter』Related information(flow rotameter|digital flow meter|balo meter|hydraulic flow meter|volumetric meter|positive displacement meter|pitot tube flow meter|displacement meter|cfm meter|variable area flow meter|inline flow meter|differential pressure flow meter|calibrated flow meter|velocity meter|paddle wheel flow meter|oval gear flow meter|anemometer hvac|multiphase flow meter|doppler flow meter|thorpe tube flowmeter|heat flow meter)

1. Technical parameters of intelligent vortex flowmeter
Nominal diameter: Pipeline type: DN4~DN200 Insertion type: DN100~DN2000 Accuracy level: Pipeline type: ± 0.5 level, ± 1.0 level Insertion type: ± 1.5 level, ± 2.5 level Environmental temperature: -20 ℃~50 ℃ Medium temperature: Measuring liquid: -20 ℃~120 ℃ Measuring gas: -20 ℃~80 ℃ Atmospheric pressure: 86KPa~106KPa Nominal pressure: 1.6 Mpa, 2.5 Mpa, 6.4 Mpa, 25 Mpa Explosion proof level: ExdIIBT4 Connection method: threaded connection, flange clamping, flange connection, insertion type, etc. Straight pipe section requirements: Gas: The upstream straight pipe section should be ≥ 10DN, the lower bundle collision straight pipe section should have a penetration of ≥ 5DN for liquid: the upstream straight pipe section should have a penetration of ≥ 20DN, and the downstream straight pipe section should have a penetration of ≥ 5DN. Insertion type: the upstream straight pipe section should have a penetration of ≥ 20DS, The downstream straight pipe section should be ≥ 7DS (DS is the measured inner diameter of the pipeline). Display mode:
(1) Remote display: pulse output, current output (with display instrument)
(2) On site display: 8-bit LCD displays cumulative flow rate, unit (m3) 4-digit LCD displays instantaneous flow rate, unit (m3/h), battery power, frequency, flow rate
(3) Temperature and pressure compensation type: A. Display standard instantaneous flow rate and standard cumulative flow rate B. Display current pressure, temperature, battery voltage output function:
(1) Pulse output, The p-p value is determined by the power supply
(2) 4-20mA two-wire current output
(3) Unit volume pulse output and sensor raw pulse output<

(4) Power supply with RS485 communication interface:
(1) DC5-24V
(2) Standard 3V lithium battery installed inside the instrument can be continuously used for more than eight years
(3) Temperature and pressure compensation type 3V lithium battery installed inside the instrument can be continuously used for more than four years Transmission distance: the distance from the sensor to the display instrument can reach 500m
2. Rotary turbine flow start stop Table steps?
① Close the exhaust valve and intake valve first. ② Slightly open the air outlet valve, then slowly open the inspection air inlet valve to slowly start the meter, and then slowly open the air outlet valve and alarm valve to achieve normal operation. It is necessary to prevent sudden start and damage to the meter core. ③ When carrying spring eggplant, the exhaust valve should be closed before closing the intake valve, and the above regulations should be followed every time it is started.
3. Working principle of intelligent vortex flowmeter
Working principle of intelligent vortex flowmeter: Intelligent vortex flowmeter is a flow measurement instrument based on fluid dynamics principles, and its working principle mainly depends on the vortex flow generated by the fluid in a specific structure and its precession phenomenon.
.First, the structural characteristics of the flow sensor. The flow profile of the intelligent vortex flowmeter flow sensor is similar to the profile of the Wenqiu Li tube Qingzi rent, which helps the fluid to form a stable flow state inside the sensor.
. On the entrance side, there is a set of spiral guide vanes. The function of these blades is to force the fluid entering the fl